CFVBC - 2004 MAGNOLIA

  • MSDS: CFVBC
  • Manufacturer: MAGNOLIA PLASTICS INC
  • Product Name: 2004 MAGNOLIA
  • National Stock Number: 8040-00F003878
Product Identification

Product ID:2004 MAGNOLIA
MSDS Date:09/13/1995
FSC:8040
NIIN:00F003878
MSDS Number: CFVBC

Responsible Party
MAGNOLIA PLASTICS INC
5547 PEACHTREE INDUSTRIAL BLVD
CHAMBLEE, GA 30341-2234
US

Emergency Phone: 800-457-4280/770-451-2777

Info Phone: 770-451-2777/800-457-4280

Cage: 22121

Contractor
MAGNOLIA PLASTICS INC
CHAMBLEE, GA 30341-2234 US

Telephone: (770) 451-2777/(800) 457-4280

Cage: 22121

Ingredients

EPOXY RESIN

Fraction By Weight: 50-60%


1-CHLORO-2,3-EPOXYPROPANE, EPICHLOROHYDRIN (SUSP ANIMAL

CAS: 106-89-8

RTECS: TX4900000

Fraction By Weight: <3%

OSHA PEL 5 PPM (SKIN)

ACGIH TLV: 2 PPM (SKIN)

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


N-BUTYL GLYCIDYL ETHER

CAS: 2426-08-6

RTECS: TX4200000

Fraction By Weight: 5-10%

OSHA PEL 270 MG/CUM

ACGIH TLV: 133 MG/CUM


GRAPHITE

CAS: 7782-42-5

RTECS: MD9659600

Fraction By Weight: 2-4%

ACGIH TLV: 2 MG/CUM RESP IC


CALCIUM CARBONATE, DOMOLITE, LIMESTONE, WHITING *97-3*

CAS: 1317-65-3

RTECS: EV9580000

Fraction By Weight: 40-50%

OSHA PEL 15 MG/M3

ACGIH TLV: 10 MG/CUM TOTAL DUST

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHALATION: MAY CAUSE IRRITATION TO
NOSE, THROAT & RESPIRATORY TRACT. INGESTION: MODERATELY TOXIC, MAY
BE HARMFUL. SKIN: SEVERELY IRRITATING & MAY BE ABSORBED. MAY CAUSE
ALLERGIC REACTION & POSSIBLE S ENSITIZER. EYES: SEVERELY
IRRITATING; PERMANENT DAMAGE POSSIBLE.
Explanation of Carcinogenicity:SEE INGREDIENTS.
Effects of Overexposure:IRRITATION.
Medical Cond Aggravated by Exposure:PRE-EXISTING SKIN & EYE DISORDERS.

First Aid

First Aid:SKIN: WASH W/SOAP & WATER. EYES: FLUSH W/WATER FOR 15 MINS.
INHALATION: REMOVE TO FRESH AIR. GIVE OXYGEN IF NECESSARY.
INGESTION: DON'T INDUCE VOMITING. GIVE LARGE DOSES OF WATER. OBTAIN
MEDICAL ATTEN TION IN ALL CASES.

Fire Fighting

Flash Point Method:PMCC
Flash Point:173F
Extinguishing Media:WATER SPRAY, FOAM, DRY CHEMICAL, CO2.
Fire Fighting Procedures:AVOID BREATHING SMOKE. IN CONFINED AREAS, USE
FULL FIRE FIGHTING EQUIPMENT & NIOSH APPROVED SCBA. COOL FIRE
EXPOSED CONTAINERS W/WATER.
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:AVOID CONTACT W/LIQUIDS & VAPORS. WIPE W/A
CLOTH/COLLECT ON ABSORBENT MATERIAL. LARGE: DIKE & CONTAIN.
PUMP/SHOVEL INTO SALVAGE VESSELS.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY AREA IN TIGHTLY
CLOSED CONTAINERS. USE W/ADEQUATE VENTILATION. FOR INDUSTRIAL USE
ONLY.
Other Precautions:AVOID CONTACT W/SKIN & EYES.

Exposure Controls

Respiratory Protection:FOR EXCESSIVE VAPORS/TO MAINTAIN TLV, A NIOSH
APPROVED RESPIRATOR FOR ORGANIC VAPORS IS NEEDED.
Ventilation:LOCAL EXHAUST/MECHANICAL (GENERAL).
Protective Gloves:IMPERVIOUS RUBBER
Eye Protection:SPLASH-PROOF CHEMICAL GOGGLES
Other Protective Equipment:IMPERVIOUS CLOTHING & BOOTS, EYE WASH
STATION, SAFETY SHOWER.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. USE GOOD HYGIENE PROCEDURES.
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:>225F
Vapor Pres:0
Vapor Density:>1
Spec Gravity:1.6
Evaporation Rate & Reference:(BU AC = 1): <1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLACK LIQUID; ODORLESS
Percent Volatiles by Volume:0

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG LEWIS ACIDS, STRONG MINERAL ACIDS.
Stability Condition to Avoid:ELEVATED TEMPS.
Hazardous Decomposition Products:CO, ALDEHYDES, ACIDS.
Conditions to Avoid Polymerization:REACTION W/SOME CURING AGENTS IN
BULK IS EXOTHERMIC.

Disposal

Waste Disposal Methods:CURE, THEN BURY/INCINERATE WHERE PERMITTED
IAW/FEDERAL, STATE & LOCAL REGULATIONS. REMOVE SALVAGE VESSELS TO
WASTE DISPOSAL SITE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.